Permit #B1900393
Address3101 WILSON BLVD
TypeCTBO
StatusFINALED
Permit HolderARMINCO INC.
Owner3101 WILSON LLC % THE JOHN AKRIDGE COMPANIES
Applied Date02/13/2019
Approved Date04/05/2019
Date Issued04/08/2019
DescriptionNEW TENANT LAY OUT FOR 1ST FLOOR UNIT 0003 FOR **FORMULA RUNNING CENTER**

  View Event Log.      View Status.       View Required Plan Review       View Printer Version.   
  
  
Search Again

 
ReviewAccessibility Review
Review Date02/19/2019
StatusRejected
Comments
COMMERCIAL PLAN REVIEW
All projects are reviewed under the requirements outlined in the Virginia Uniform Statewide Building Code. A written response letter must accompany plan revisions. Please contact the Plan Examiner for any clarification of the comments.
Permit #:    B1900393    Applicable Code:    VUSBC 2012 Edition
Project Name:    Formula Running Center    Plan Examiner:    Chris Martin
Address:    3101 Wilson Blvd    Discipline:     Accessibility
Review Date:    2/19/19    Phone Number:    703-228-3854
Review #:    1st    Fax Number:    703-228-7046
Revision Date:        Email:    cmmartin@arlingtonva.us
            
    Sheet    Comments    Code Reference
        Accessibility plan review comments    
1    A-1.0    Transfer showers shall be 36 inches x 36 inches    ANSI 608.2.1.1
2    A-1.0    A clearance of 48 inches (1220 mm) minimum in length measured perpendicular from the control wall, and 36 inches (915 mm) minimum in depth shall be provided adjacent to the open face of the compartment.    ANSI 608.2.1.2
3    A-1.0      The front partition and at least one side partition shall provide a toe clearance of 9 inches (230 mm) minimum above the floor and extending 6 inches (150 mm) beyond the compartment side face of the partition, exclusive of partition support members.    ANSI 604.9.5.1
        Further comments may be forthcoming upon plan resubmission.     
  



  
 